Checking the axial clearance of the camshaft
Note.
- Necessary special devices, control and measuring devices, as well as auxiliary means:
- Universal Dial Indicator Holder (MP 3-447).
- Clock indicator.
Note. The measurement should be carried out with the hydraulic compensators removed and the cylinder head cover removed.
Load the camshaft on the middle camshaft bearing cap. Wear limit: no more than 0.20 mm.
Valve sizes
Note. Valves cannot be reworked. Only mutual lapping with the appropriate seat using lapping paste is allowed.