Release coolant hose "2". Unlock the clamps "arrows", remove the upper part of the air duct "1".

Unscrew the screw "arrow" on the left and right. Unhook and remove the lower part "1" of the air duct.

Disconnect the electrical connector "arrow".

Unscrew the oil pressure sensor "F1".
Installation
Installation in reverse order.
Note: Replace the sealing ring. Check the oil level.