For vehicles with engine code CRVC
Remove the neutralizer. Drain coolant. Loosen clamp -1- and detach hose. Loosen the nuts - see arrows-. Secure the coolant pipe at the top, eg with cable clamps.
Unscrew bolts -1- using socket -T10347-, loosen nuts -2-. Remove connecting tube -A-.
Open clamps -arrows-, disconnect coolant hoses and unscrew exhaust gas recirculation temperature sender -G98- -1- using suitable wrench from set -T10395 A-.
Loosen screws -1- using XZN 10 tool -T10501-, unscrew bracket for vacuum line -2-. Disconnect vacuum line from exhaust gas recirculation cooler.
Release screws -arrows- and remove exhaust gas recirculation cooler -A- carefully through tunnel.
Installation
Installation in reverse order.
Note: Replace self-locking nuts and screws as well as O-rings and seals after removal. Use factory-installed clamps to secure all hoses. Install the cable ties in the appropriate places.
Install the neutralizer. Fill up the coolant.