Connecting and disconnecting the refrigerant circuit piping to the compressor
Note: Extract the refrigerant using an air conditioner service stand. After disconnecting, close the refrigerant lines and compressor fittings with plugs to protect against moisture from the air.
1. 23 Nm
2. Connecting fitting of the high pressure pipeline; anti-twist with centering sleeve
3. Low-pressure connection: anti-twist with dowel sleeve
4. O-ring (low pressure circuit)
5. Centering sleeve
6. O-ring groove
7. O-ring of circular cross-section (high pressure circuit)
Connecting and disconnecting the refrigerant circuit piping to the condenser
Note: After removal, plug the refrigerant lines and the condenser fittings with suitable plugs to prevent moisture from entering.
1. Screws, 10 Nm
2. Refrigerant piping
3. O-rings
3. Refrigerant line connection: anti-twist with dowel sleeve
4. Connection for the condenser