Release coolant hose -2-. Unlock catches -arrows-, remove top section of air duct -1-.
Disconnect electrical connector -2- from mass air flow meter -G70-. Detach vacuum hose -4-. Loosen hose clamp -3- and remove air hose. Remove air filter -1-.
Installation
Installation in reverse order.
Note: The unions, pipes and hoses of the pressurization system must be degreased before installation. Use a silicone-free lubricant to install the air fittings. Use only approved spring clamps to secure hose connections.
Disconnect drain hose -arrow-. Clean the nozzle, the bottom of the air filter and the hose from dirt and leaves.
Pay attention to mounting markings -arrows- when connecting intake manifold connection to air cleaner housing. Install the air filter on the battery bracket and press until you hear a distinct click. Press down on the air filter again and then pull it back to check if the latches are properly latched.