Removing
1. Disconnect the negative cable from the battery.
2. Remove the blower/fresh air motor from the heater block and disconnect the wires from the heater (see chapter 11).
3. Remove the panel of the central switch of modes of heating/ventilation of salon which is located over levers of management of a heater.
4. Pull the blower control handle off the mode switch, then unscrew the mounting nut and push the switch out through the panel (see photo).
5. Separate switch wires from connector (located in the panel, to the right of it), then remove the switch by passing the wires of the blower motor through the baffle (see photo).
6. If the reason for removing the switch was problems with the operation of the supercharger at low and / or medium speeds, check the resistor of the supercharger motor (see chapter 11).
Installation
7. Install in reverse order. Make sure the wiring is connected securely.